Sage Metering

Sage Metering

SAGE PRIMEโ„ข THERMAL MASS FLOW METER FOR GASES

Sage Prime is the top selling meter in our Product Line. The Sage Prime Thermal Mass Flow Meter features a bright, high contrast, photo-emissive OLED (Organic LED) display of Flow Rate, Total and Temperature in a robust, yet lightweight, dual-sided NEMA 4 enclosure. The Flow Rate is also displayed graphically in a horizontal bar graph format. The rear compartment is completely separated from the electronics, and has large, easy-to-access, well marked terminals, for ease of customer wiring (see photo below). It is powered by 24VDC (12VDC optional, or 115/230VAC). The power dissipation is under 2.5 watts (e.g. under 100 mA at 24VDC).

ย 

The Sage Prime Flow Meter is offered in Integral or Remote style (which has lead-length compensation up to 1000 feet as well as an Explosion Proof Junction Box). Specify any standard probe length or ๏ฌ‚ow body size. It has a 4-20 mA output as well as a pulsed output of Totalized Flow (solid state transistor drive). In addition, Sage Prime supports full Modbusยฎ compliant RS485 RTU communi cations (IEEE 32 Bit Floating Point).

Sage Prime is CE approved, and CSA, UL approved for Hazardous Service1 (see โ€œApprovalsโ€under the โ€œKnowledge Baseโ€ tab on the website). For ATEX Zone I approvals, request Sage Rio Flyer (SIX Series).

ย 

CONTINUOUS DIAGNOSTICS & FIELD CONFIGURABILITY

Sage Prime has continuous diagnostics. The raw calibration milliwatts (mw) isย 

always displayed in the upper left hand corner of the meterโ€™s display. At any time, you can check this reading at a โ€œNo Flowโ€ (0 SCFM) con dition, and compare the reading to the original re ported โ€œNo Flowโ€ value noted on the last few lines of your meterโ€™s Certi ๏ฌcate of Con formance or the Flow Meterโ€™s data tag. This in-

situ diagnostic procedure not only checks the sensor performance and the โ€œLive Zeroโ€ calibration point, but it also veri๏ฌes that the sensor is clean. It essentially provides a means to validate that the meter is oper ating properly, veri๏ฌes thatย 

there is no shift or drift, and eliminates the need for annual fac tory calibrations. This simple ๏ฌeld diag nostic procedure, in addition, veri๏ฌes that the sensor is free from contami nation, even without inspection. Although Sage Prime is fully con๏ฌgured upon shipment for the pipe and process cond itions requested, if changes are needed, SageComโ„ข software is optionally available for ๏ฌeld recon๏ฌgurability and performance validation and a printed report.

ย 

MAJOR BENEFITS OF THERMAL MASS FLOW METERS

  • Direct Mass Flow โ€“ No need for separate temperature or pressure transmitters
  • High Accuracy and Repeatability โ€“ Precision measurement and extraordinary repeatability
  • Turndown of 100 to 1 and resolution as much as 1000 to 1
  • Low-End Sensitivity โ€“ Measures as low as 5 SFPM (e.g., 1 SCFM in a 6โ€ณ pipe)
  • Negligible Pressure Drop โ€“ Will not impede the ๏ฌ‚ow or waste energy
  • No Moving Parts โ€“ Eliminates costly bearing replacements, and prevents undetected accuracy shifts
  • Dirt Insensitive โ€“ Provides sustained performance
  • Ease of installation and convenient mounting hardware

SPECIFIC BENEFITS OF THE SAGE PRIME

  • Features in-situ Calibration Veri๏ฌcation Procedure of sensorโ€™s performance โ€“ veri๏ฌes that the sensor is clean, and assures that there is no drift, or shift in the ๏ฌ‚ow meter
  • Compact design of enclosure is only 41โ„ 2โ€ณ dia. by 43โ„ 8โ€ณ deep (DC Models)
  • High contrast photo-emissive OLED display with numerical Flow Rate, Total and Temperature, as well as Graphical Flow Indicator
  • Calibration milliwatts (mw) is continuously displayed, providing for ongoing diagnostics
  • Measures velocities as high as 35000 SFPM (e.g., 3100 SCFM in a 4โ€ณ Pipe)
  • Proprietary digital sensor drive circuit provides enhanced signal stability and unaffected by process temperature & pressure changes
  • Modbusยฎ compliant RS485 RTU communications
    Isolated 4-20 mA output and pulsed output of Totalized Flow
  • Rugged, user-friendly packaging with easy terminal access
  • Remote style has Lead-Length Compensation. Allows remote electronics up to 1000 feet from probe; Explosion Proof Junction Box has no circuitry, just terminals (suitable for harsh environments)
  • Low power dissipation, under 2.5 Watts (e.g. under 100 mA at 24VDC)
  • Field recon๏ฌgurability via optional SageComโ„ข validation and con๏ฌgu ration software
    Flow conditioning built into In-Line ๏ฌ‚ow meters (1/2โ€ณ and up)
  • Captive Flow Conditioners for Insertion meter applications, if required

SAGE PRIMEโ„ข STYLES AND SPECIFICATIONS

Sage Metering is your source for monitoring, measuring and controlling the gas mass ๏ฌ‚ow in your industrial process, building management system or environmental application. Our high performance, NIST Traceable, Thermal Mass Flow Meters will help in crease productivity, reduce energy costs, maximize product yields, and/or help reduce environmental insult.

Sage provides high quality In-Line and Insertion Thermal Mass Flow Meters for a wide variety of industrial, commercial, and environmental monitoring needs, including carbon credit veri๏ฌcation for Greenhouse Gas reduction.

Our experienced application engineers, many of whom have worked in the Thermal Mass Flow marketplace since its inception, will assist you in choosing the proper gas Flow Meter for your applicationโ€”and they will be pleased to offer installation guidance to assure that the meter(s) selected will perform as accurately as possible. Additionally, our Service Staff stand ready to support you with any after-sale assistance that you may require.

PRIME SIP/SRP

Standard accuracy is +/โ€“ 0.5% of Full Scale +/โ€“ 1% of reading with a turn- down of 100 to 1 and resolution as much as 1000 to 1. Repeatability is 0.2%. NOTE: Enh anced accuracy optionally available with limited turn-down4.
The electronics has an isolated 4 to 20 mA output proportional to Mass Flow Rate as well as pulsed outputs of Totalized Flow (24VDC solid state transistor drive6). In addition, Modbus RS485 RTU communications is standard (IEEE 32 Bit Floating Pt).

INTEGRAL STYLE ELECTRONICS7

Electronics is Integral style, with rugged windowed dual compartment NEMA 4 enclosure with local display. The display is a high contrast photo-emissive OLED display, and displays Mass Flow Rate, Totalized Flow and Temperature as well as a graphical representation of Flow Rate in a horizontal bar graph format. In addition, the calibration milliwatts (mw) is continuously displayed, providing ongoing diagnostics.

REMOTE STYLE ELECTRONICS

Electronics is Remote style, with rugged windowed dual compartment NEMA 4 enclosure with display. The display is a high contrast photoemissive OLED display, and displays Mass Flow Rate, Totalized Flow and Temperature as well as a graphical representation of Flow Rate in a horizontal bar graph format. In addition, the calibration milliwatts (mw) is continuously displayed, providing ongoing diagnostics. Includes Remote Mounting Hardware.

The Flow Elementโ€™s Junction Box is Expl Proof (Class 1, Div 1, Groups B, C, D), and does not have any electronicsโ€”only a wiring terminal block. The Junction Box is connected to the Remote Electronics by 25 ft of lead-length compensated cable. The cable (6-conductor) can be lengthened or shortened without affecting accuracy (max loop resistance 10 ohms, over 1000 ft), if grounded properly, at transmitter.

ENGINEERING SPECIFICATIONS OF OPTIONAL SAGE PRIME PLUS

This is an optional version of Sage Prime offering a separate ground for the 24VDC Power Supply (optional 5VDC or 12VDC Power Supplies) which isolates the Modbus ground from the power supply ground. All other features of Prime PLUS are identical to the standard Sage Prime, except Approvals do not apply at this time.

  1. Male NPT ends are standard, with ๏ฌ‚anged ends, tube, or butt weld optionally available
  2. Mounting hardware such as Isolation Valve Assemblies, Compression Fittings, and Flanges, are optional
  3. Chart of Flow Body length โ€œXโ€ is on table on the right
  4. Enhanced accuracy available upon request, especially if turndown limited. Contact Sage
  5. Flow Conditioners are built into In-Line style ๏ฌ‚ow bodies from 1โ„2โ€ณ to 4โ€ณ
  6. 10 Amp Dry Contact external relay available for Totalized Flow (specify DCR-DC accessory)
  7. If NEMA 4X enclosure or HART needed, specify Sage Paramount (Series 401)

Contact Us